Energy Master Plan
Where Thurles Sports Clubs SEC stands today, and what the plan changes by 2030.
Where we are now
Published · 16 November 2026- 633 homes
- 425 with a BER (67%)
- 575 households
- 1,455 residents
- 753 cars
- 80 business premises
- 23 public & community buildings
Estimated annual energy, emissions and cost for the sectors in this plan. Based on 5 Small Areas in Thurles Urban and Thurles Rural, Co. Tipperary
Source (SEAI BER profile + Census ’22) +
BER counts, ratings and heating fuel from SEAI’s BER data by Small Area, published 6 October 2026, copied 6 Oct 2026, 16:09 (425 of 633 homes rated); dwelling detail from a sample of SEAI BER Register records; CSO Census 2022 SAPS for household counts and heating fuel, Tailte Éireann valuation floor areas for business, and SEAI emission factors and unit prices.
Where the community is
Energy by sector
Read more
| Residential | 10.6 | 14.7% | 2,074 | €1,820,766 |
|---|---|---|---|---|
| Transport | 7.2 | 10.0% | 1,675 | €1,049,472 |
| Business | 46.7 | 64.9% | 9,768 | €8,044,125 |
| Farming | 3.7 | 5.1% | 819 | €620,200 |
| Public & community | 3.8 | 5.3% | 746 | €673,506 |
| Total | 72.0 | 100% | 15,083 | €12,208,069 |
Source (EMP baseline + SEAI factors) +
What kind of energy the community buys
Read more
- Electricity19%13.5 GWh
- Fossil fuel68%48.9 GWh
- Renewable13%9.7 GWh
Source (EMP tables T1–T3) +
About this plan +
A summary of Thurles Sports Clubs SEC’s Energy Master Plan: how much energy the community uses today, what that costs, what the plan would change by 2030, and each chapter of the plan in brief. The full plan document has the detail behind every figure.
Where all of this comes from +
- SEAI BER data by Small Area (EMP Map) — homes with a BER, ratings on the old and new scales, heating fuel and residences — published 6 October 2026, copied 6 Oct 2026, 16:09
- SEAI BER Register — fabric, floor areas and energy detail for a sample of rated homes — assessment dates vary by record
- CSO Census 2022 Small Area Population Statistics — households, heating fuel, car ownership — 2022
- Pobal HP Deprivation Index — relative affluence by Small Area — 2022
- Tailte Éireann valuation records — rateable floor areas by category — 2025
- EU JRC PVGIS — solar yield — v5.3
- ESB Networks customer capacity heatmap — spare capacity at local substations — retrieved 2026-11-02
- SEAI SEC Energy Master Plan grant data — grants paid in Northern Tipperary Development Company — running totals, retrieved 2026-11-16
- Energy factors and indicative tariffs — values saved in plan assumptions — mixed source periods; see assumptions
Things to be careful about +
- Space and water heating: SEAI National Heat Study averages by BER band (Settings → CSO band energy) for SEAI’s published band counts, expanded to every home. Metered Irish homes use about these amounts whatever their rating (Coyne & Denny 2021).
- The heat is split by main heating fuel from SEAI’s profile. Heat-pump homes use electricity at the useful heat ÷ SCOP 3; direct-electric homes at the useful heat (boiler-equivalent efficiency 95%).
- Lighting and pumps/fans come from the BER certificates, expanded to every home.
- Appliances and cooking add 2,900 kWh of electricity a year per occupied home (SEAI Energy in the Residential Sector 2018, 2016 national average, less certificate lighting). This is an editable assumption.
- Existing on-site generation is not deducted without evidence of self-consumption. Additional PV is assessed separately against remaining electricity demand.
- A modelled estimate, not this community’s metered use. The certificate method is available in Settings → Residential method.
- Annual savings use the saved retrofit rollout; additional solar and EV uptake ramp evenly over the same years. Each completed year is treated as a full operating year, with fixed saved prices and carbon factors. Cumulative savings sum annual run rates once.
- The renewable comparison is additional on-site solar used locally divided by included delivered energy. It excludes unverified existing generation and is not a national renewable-energy share.
- Annual self-use is an assumption capped by remaining electricity demand, not an hourly generation/load simulation.
- Retrofit suitability, costs and performance are planning assumptions requiring building-level assessment.
- Transport is a resident-travel model for the selected age-15-plus population. Mode distances and occupancy are assumptions; Census cars are contextual counts, not the multiplier for these totals.
- Travel uses the NTA National Household Travel Survey 2023 figures for the Urban town area type (10.74 km average trip), from the CSO urban/rural classification of the Small Areas. Each mode takes its own trip length from the CSO National Travel Survey 2016 (a car journey 1.15 times the average, a walk a seventh of it), a departure from the SEAI template, which gives every mode the average length and so understates car travel.
- Agriculture uses approximate farm allocation and per-farm energy assumptions. It covers energy-related CO2 only, excluding livestock methane and soil/fertiliser emissions.
- BER coverage is 67%. BER coverage does not establish sample representativeness; estimates for unrated homes depend on the model assumptions.
- Business and community energy is benchmarked from floor area, not metered — replace benchmarks with a year of bills where the committee has them.
- Every 2030 figure assumes 60% of the plan is delivered.
- Energy demand and costs are modelled estimates, not household bills. BER certificates describe standardised use; defaults and any local overrides require review.
- Some records lack complete delivered-energy costs and are excluded from the energy-cost risk calculation.