How the residential baseline is calculated

Heat per BER band split by heating fuel, certificate lighting and pumps, and an appliances allowance, expanded to every home — and what the cross-check shows.

The community baseline on Residential → Energy Baseline is the figure the plan uses. It is built in four steps.

  1. Space and water heating: SEAI’s count of homes in each BER band × the National Heat Study’s average heat for that band (the same figures as the EMP workbook), expanded to every home. Metered Irish homes use roughly these amounts whatever their rating.
  2. That heat is split by main heating fuel from SEAI’s profile. Oil, gas and solid-fuel homes burn it as that fuel; direct-electric homes use electricity; heat-pump homes use a third as much electricity (SCOP 3).
  3. Lighting and pumps come from the BER certificates, and appliances and cooking, which a BER does not model, add an assumed amount of electricity per occupied home (2,900 kWh a year by default, from SEAI’s national estimate).
  4. Every fuel is priced and converted once with the factors in Settings: € and CO₂ per delivered kWh, and a primary energy factor (grid electricity 1.739, fuels 1.0, as in SEAI’s energy statistics).

Settings → Residential method can switch heating to each certificate’s own energy instead, scaled by rating towards metered use. It follows each home’s fabric and fuel more closely but relies on the certificates.

The certificate cross-check

The cross-check adds up the BER certificates themselves. Certificates use the conversion factors of their assessment year and cover only the loaded records, so the totals differ from the baseline; they are context, not a second baseline.